一个无监督的图像增强框架用于绝缘体的多重故障检测
Jiaxin Guo1, Gujing Han1, Min He1,2
1School of Electronics and Electrical Engineering, Wuhan Textile University, Wuhan 430200, China.
Sensors (Basel, Switzerland)
|November 27, 2025
概括
本研究介绍了用于输电线路检查的无监督图像增强方法. 该技术在复杂的照明条件下改善了亮度平衡和缺陷检测准确度.
科学领域:
- 计算机视觉 计算机视觉
- 图像处理 图像处理
- 电气工程 电气工程
背景情况:
- 传输线路检查需要高质量的图像.
- 复杂的照明条件会导致亮度不均,降低检测准确度.
- 现有的方法在不同的照明下难以进行无监督的增强.
研究的目的:
- 开发一种无监督的图像增强方法,用于输电线路检查.
- 在复杂的照明条件下提高检测精度.
- 为了解决检查图像中亮度分布不均的问题.
主要方法:
- 提出了一个无监督的方法,整合了灰度特征指导和亮度一致性损失.
- 设计了一台U形发电机,具有深度可分离的卷积,用于多级特征提取.
- 包含一个灰度特征引导模块和光度一致性损失,用于自适应增强和亮度平衡.
- 使用多级别的分辨器来增强全球和本地发光度的区别.
主要成果:
- 显著改善图像质量指标:峰值信号噪声比 (PSNR) 从7.73增加到18.41.
- 结构相似度指数 (SSIM) 从0.43提高到0.85.
- 改进的图像导致在输电线路检查中提高了缺陷检测准确度.
结论:
- 拟议的无监督方法有效地增强了复杂照明下的输电线路检查图像.
- 灰度指导和亮度一致性损失对于自适应增强和亮度平衡至关重要.
- 该方法提高了整体图像质量和随后的缺陷检测准确度.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
2.1K
08:27Author Spotlight: Efficient Image Recognition Using Directional Gradient Histogram Technique and Support Vector Machines
Published on: January 5, 2024
1.6K
相关概念视频
Fault Types
389
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
389
Insulation Coordination
546
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
546
Power System Three-Phase Short Circuits
509
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
509
Line Protection with Impedance Relays
419
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
419
Bus Impedance Matrix
489
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
489
Three-Phase Short Circuit—Unloaded Synchronous Machine
649
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
649