Development and evaluation of a linear regression method for the prediction of maximal chiral separation of basic

A Van Eeckhaut1, S Boonkerd, M R Detaevernier

  • 1Department of Pharmaceutical Chemistry and Drug Analysis, Pharmaceutical Institute, Vrije Universiteit Brussel, Brussels, Belgium.

Related Concept Videos

Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Chromatographic Resolution01:15

Chromatographic Resolution

In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Racemic Mixtures and the Resolution of Enantiomers02:30

Racemic Mixtures and the Resolution of Enantiomers

A racemic mixture, or racemate, is an equimolar mixture of enantiomers of a molecule that can be separated using their unique interaction with chiral molecules or media. Racemic mixtures are denoted by the (±)- prefix. This ‘optical rotation descriptor’ applies to the whole solution of a racemic mixture rather than a specific stereoisomer. Enantiomers typically have the same physical and chemical properties. Hence, they are not easily separable. However, enantiomers can exhibit different...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
Principles Of Column Chromatography01:13

Principles Of Column Chromatography

The chromatography technique was first invented in 1901 by Michael S. Tswett, a Russian botanist, to separate plant pigments using organic solvents. Further, in 1941, Archer John Porter Martin and R. L. M. Synge modified the technique by packing silica gel into a column. A mixture of amino acids was then separated on the packed column using chloroform and water mixture as the mobile phase. This was the first report on column chromatography. At present, column chromatography is a widely used...
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...