Error analysis of a natural breathing calibration method for respiratory inductive plethysmography
Related Experiment Video
Updated: Oct 5, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
1Department of Biomedical Engineering, Linköping University, Sweden. tomst@imt.liu.se
Abstract:
Respiratory volumes are measured non-invasively by recording rib cage and abdominal motions using respiratory inductive plethysmography (RIP). Qualitative diagnostic calibration (QDC) of RIP is based on the natural variability in the relative rib-cage-to-abdomen contribution during tidal breathing. ODC does not require subject cooperation but it has previously been shown that accuracy may deteriorate when breathing pattern changes. The aim of this study was to investigate the causes and situations where QDC accuracy deteriorates. The QDC method was compared to PRA (calibration during voluntarily preferential rib cage or abdomen breathing) in ten adults. A reference RIP calibration was obtained from all validation data (REF). The PRA method had better accuracy than the ODC method (p<0.01). The volumetric error ranged between 10% and 136% with QDC and between 5% and 33% with PRA. The PRA calibration factors were within 6% of those from REF, while the QDC rib-cage factor was underestimated by 15% and the abdominal factor was overestimated by 38%. Small natural variability in the relative rib-cage-to-abdomen contribution was related to poor accuracy. Each compartment's variability depended on its magnitude, which is a violation of the QDC assumptions.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Respiratory Volumes and Capacities I
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration