Abstract:
Motion artifacts have been identified as a problem in medical tomography systems. While computed tomography (CT) imaging has been getting faster, there remains a need to detect and compensate for motions in clinical follow-up of neurological patients (multiple sclerosis, tumors, stroke, etc.), in cardiac imaging, and in any area in which failing to detect a motion artifact may lead to misdiagnosis. We have developed a novel algorithm to detect motion in brain images. The algorithm deals with detecting and isolating motion in the object domain using only the information available in the sinogram domain. The new "opposite ray algorithm" (ORA) addresses the issue of motion in the interior elements of the object. The ORA combines information from projections that are opposite in space and separated in time to isolate and identify the motion. A sinogram of motion is created, integrated and reconstructed to isolate the moving component. The algorithm can be used with conventional clinical scanners employing quarter-detector offset. The significant effect of quarter-detector offset on the ORA is investigated. The effects that a finite beamwidth and noise have on the ORA are also investigated. Both the similarity index and a correlation coefficient are used to evaluate the algorithm. The algorithm is successful when applied to cases exhibiting translational and translational-rotational motion. A similarity index of 0.88 is obtained in a typical case with both translational and rotational motion. Further development is recommended in the deformation case.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT