Related Experiment Videos
The partial-punch: a new combined cataract-glaucoma operation
Abstract:
This report describes a new combined cataract extraction-glaucoma procedure. The technique is a modification of a standard filtration type of operation. The essential step is the development of a shelved posterior scleral lip, 4 mm of which is excised; full thickness sclera is not removed. This permits tight incisional closure, but with the presence of a "valve" permitting exit of aqueous under a prepared conjunctival flap should intraocular pressure rise significantly in the postoperative period. In 15 cases there were no serious complications, no flat anterior chamber, good pressure control in 14 cases, and filtering blebs in nine.