Related Experiment Videos
Extravasal occlusion of large vessels with titanic clips: efficiency, indications, and contraindications
Yu V Vasilenko1, A I Kim, S A Kotov
1Department of Faculty Surgery, Russian State Medical University, Moscow.
Bulletin of Experimental Biology and Medicine
|June 13, 2003
Abstract:
The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.