Efficacy of implantable loop recorders in establishing symptom-rhythm correlation in young patients with syncope and
Joseph Rossano1, Beatrijs Bloemers, Narayanswami Sreeram
1Department of Pediatrics, University of Washington School of Medicine, Seattle, USA.
Objective:
To evaluate efficacy of the recently introduced implantable loop recorder (ILR) in establishing symptom-rhythm correlation in young patients with syncope, near syncope, palpitations, and acute life-threatening events (ALTEs).
Methods:
A retrospective study was conducted with patients with ILR from 3 pediatric centers. Inclusion criteria were age
Results:
Twenty-one patients (12 male, 9 female) with an average age of 12.3 +/- 5.3 years (range: 0.8-22 years) were included in the study. Five (24%) patients had structural heart disease, 2 (10%) had a family history of sudden cardiac death, 3 (14%) had QT prolongation on electrocardiogram, and 11 had no cardiovascular disease. Indications for ILR were recurrent syncope and near syncope (n = 15), palpitations (n = 2), and ALTE (n = 2). Fourteen (67%) patients continued to have symptoms, and 7 (33%) had no symptoms after ILR over a follow-up period of 8.4 +/- 4.7 months (range: 1.9-16 months). Symptom-rhythm correlation was possible in all 14 patients who continued to have symptoms (supraventricular tachycardia in 4, ventricular tachycardia in 2, torsades de points in 1, asystole in 1, junctional bradycardia in 1, and sinus rhythm in 5).
Conclusions:
ILR is useful in determining the presence or absence of an arrhythmia during symptoms of syncope, near syncope, and palpitations as well as ALTEs in patients with and without structural heart disease when conventional diagnostic testing, such as electrocardiogram, Holter monitoring, and/or external loop recording, is inconclusive.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Dysrhythmias V: Evaluating Dysrhythmias
Holter Monitor: 24-Hour Monitoring
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias I: Introduction