Magnification mismatches between micrographs: corrective procedures and implications for structural analysis.

A Aldroubi1, B L Trus, M Unser

  • 1Biomedical Engineering and Instrumentation Program, National Institute of Arthritis, Musculoskeletal and Skin Diseases, National Institutes of Health, Bethesda, MD 20892.

Ultramicroscopy
|October 1, 1992
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Activated STING in a vascular and pulmonary syndrome.

The New England journal of medicine·2014
Same author

Autonomous and self-sustained circadian oscillators displayed in human islet cells.

Diabetologia·2012
Same author

An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images.

International journal of biomedical imaging·2012
Same author

3-D PSF fitting for fluorescence microscopy: implementation and localization application.

Journal of microscopy·2012
Same author

Realistic analytical phantoms for parallel magnetic resonance imaging.

IEEE transactions on medical imaging·2011
Same author

Sum and difference histograms for texture classification.

IEEE transactions on pattern analysis and machine intelligence·2011
Same journal

Predictive drift compensation of multi-frame STEM via live scan modification.

Ultramicroscopy·2026
Same journal

Deep PACBED: Multitask analysis of PACBED images using deep neural networks.

Ultramicroscopy·2026
Same journal

Guided progressive reconstructive imaging: A new quantization-based framework for low-dose, high-throughput and real-time analytical ptychography.

Ultramicroscopy·2026
Same journal

Brightness optimization in a 200 keV DTEM source by geometry-driven aberration suppression.

Ultramicroscopy·2026
Same journal

Characterization of the Timepix4 hybrid pixel detector and its impact on four-dimensional scanning transmission electron microscopy (4D-STEM).

Ultramicroscopy·2026
Same journal

Contamination analysis of the residual gas composition in transmission electron microscopy.

Ultramicroscopy·2026
See all related articles

Accurate cryo-electron microscopy (cryo-EM) requires precise magnification calibration. New algorithms correct magnification disparities in electron micrographs, enhancing structural analysis accuracy for biological macromolecules.

Area of Science:

  • Structural biology
  • Electron microscopy
  • Biophysics

Background:

  • Quantitative structural analysis in cryo-electron microscopy (cryo-EM) necessitates integrating data from multiple micrographs and within individual images.
  • Magnification inconsistencies, caused by lens distortions, limit the achievable resolution in cryo-EM analyses.
  • A 2% magnification discrepancy can restrict resolution to approximately 5 nm for 100 nm particles.

Purpose of the Study:

  • To develop and present algorithms for cross-calibrating magnifications across different micrographs and within single micrographs.
  • To address the challenge of magnification disparities in quantitative structural analysis of biological macromolecules.
  • To improve the accuracy and resolution of cryo-EM studies by correcting for magnification errors.

Main Methods:

Related Experiment Videos

  • Derivation and description of a family of algorithms for cross-magnification calibration.
  • Application of algorithms based on the assumption of identical particle sizes, particularly suitable for cryo-electron micrographs.
  • Testing the algorithms on icosahedral virus capsids to assess accuracy and stability.

Main Results:

  • The developed algorithms accurately cross-calibrate magnifications, achieving 0.1-0.2% accuracy for icosahedral virus capsids with at least five particles.
  • The algorithm demonstrates stability against typical noise levels encountered in cryo-EM data.
  • The method is adaptable to non-isometric particles and can differentiate subpopulations of slightly varying sizes.

Conclusions:

  • The new algorithms effectively correct magnification errors in cryo-electron micrographs, enabling higher resolution structural analysis.
  • This approach is crucial for precise quantitative structural determination of biological macromolecules using cryo-EM.
  • The algorithms offer a robust and versatile tool for advancing cryo-EM data processing and analysis.