A cellular reaction to antibody in tissue culture studied with electron microscopy

The reaction of embryonic chick heart cells grown in tissue culture to specific guinea pig antiserum has been studied with electron microscopy. Heart fragments from chick embryos were cultured with a plasma clot. After being tested with antiserum or normal serum, they were fixed with buffered osmium tetroxide and embedded in butyl methacrylate before removal from the glass culture chamber. Thin cells found by phase microscopy to have reacted were sectioned in a plane parallel to the glass surface on which they had grown. The results confirm and extend observations made previously while the reactions were occurring. The plasma membrane, like that of the red cell, becomes disrupted or less resistant to trauma following the action of antiserum. The membranes of mitochondria and endoplasmic reticulum vesiculate and swell. Before nuclear shrinkage becomes prominent, the outer nuclear membrane separates over a large portion of the nuclear envelope and forms one or more large swollen blebs. Thus, the outer nuclear membrane shows a reactivity similar to endoplasmic reticulum. It is suggested that the various physical and chemical changes observed to follow the action of antibody and complement on fibroblasts may be explained by osmotic pressure differences between various cell components. Some basic similarities to the action of hemolytic agents on red cells are noted.

Related Concept Videos

Immunogold Electron Microscopy01:20

Immunogold Electron Microscopy

Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
Antibody Structure01:10

Antibody Structure

Overview
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...
Studying the Cytoskeleton01:17

Studying the Cytoskeleton

The cytoskeletal architecture can be studied using different microscopic and biochemical techniques. Electron microscopy was instrumental in discovering the cytoskeletal architecture around the 1960s, which allowed obtaining structural information at a high-resolution level. However, the sample preparation procedure often limits this ability in biological samples. Several protocols have been developed over the years to optimize sample preparation. In one of the protocols known as rotary...