Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Valve-based comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection:
Amanda E Sinha1, Bryan J Prazen, Carlos G Fraga
1Center for Process Analytical Chemistry, Department of Chemistry, Box 351700, University of Washington, Seattle, WA 98195-1700, USA.
Abstract:
A valve-based comprehensive two-dimensional gas chromatograph coupled to a time-of-flight mass spectrometer (GC x GC/TOFMS) is demonstrated. The performance characteristics of the instrument were evaluated using a complex sample containing a mixture of fuel components, natural products, and organo-phosphorous compounds. The valve-based GC x GC, designed to function with an extended temperature of operation range, is shown to have high chromatographic resolution, high separation efficiency and low detection limits. Typical peak widths at base are nominally from 100 to 300 ms on column 2 and nominally 10 s on column 1. The injected mass and injected concentration limit of detection (LOD), defined as 3 standard deviations above the mean baseline noise, for three organo-phosphorous compounds (triethylphosphorothioate (TEPT), dimethyl methyl phosphonate (DMMP) and dimethyl phosphite (DMP)) in a complex environmental sample were from 6 to 38 pg, and 3 to 17 ng/ml, respectively. The temperature program for the environmental sample ranged from 40 to 230 degrees C, a temperature range capable of analyzing semi-volatile compounds. A new compact, stand-alone, valve-pulse generator device has been implemented and is also reported. The valve-based GC x GC instrument, therefore, offers a simple, rugged and less expensive alternative to thermally modulated instruments.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Tandem Mass Spectrometry
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...