Published on: June 27, 2025
Orthostatic blood pressure control before and after spaceflight, determined by time-domain baroreflex method
J Gisolf1, R V Immink, J J van Lieshout
1Department of Physiology, Rm. M01-215, Academic Medical Center, University of Amsterdam, PO Box 22700, 1100 DE Amsterdam, The Netherlands. j.gisolf@amc.uva.nl
Abstract:
Reduction in plasma volume is a major contributor to orthostatic tachycardia and hypotension after spaceflight. We set out to determine time- and frequency-domain baroreflex (BRS) function during preflight baseline and venous occlusion and postflight orthostatic stress, testing the hypothesis that a reduction in central blood volume could mimic the postflight orthostatic response. In five cosmonauts, we measured finger arterial pressure noninvasively in supine and upright positions. Preflight measurements were repeated using venous occlusion thigh cuffs to impede venous return and "trap" an increased blood volume in the lower extremities; postflight sessions were between 1 and 3 days after return from 10- to 11-day spaceflight. BRS was determined by spectral analysis and by PRVXBRS, a time-domain BRS computation method. Although all completed the stand tests, two of five cosmonauts had drastically reduced pulse pressures and an increase in heart rate of approximately 30 beats/min or more during standing after spaceflight. Averaged for all five subjects in standing position, high-frequency interbeat interval spectral power or transfer gain did not decrease postflight. Low-frequency gain decreased from 8.1 (SD 4.0) preflight baseline to 6.8 (SD 3.4) postflight (P = 0.033); preflight with thigh cuffs inflated, low-frequency gain was 9.4 (SD 4.3) ms/mmHg. There was a shift in time-domain-determined pulse interval-to-pressure lag, Tau, toward higher values (P < 0.001). None of the postflight results were mimicked during preflight venous occlusion. In conclusion, two of five cosmonauts showed abnormal orthostatic response 1 and 2 days after spaceflight. Overall, there were indications of increased sympathetic response to standing, even though we can expect (partial) restoration of plasma volume to have taken place. Preflight venous occlusion did not mimic the postflight orthostatic response.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.