Related Experiment Video
Updated: Aug 19, 2026

Using Microwave and Macroscopic Samples of Dielectric Solids to Study the Photonic Properties of Disordered Photonic Bandgap Materials
Published on: September 26, 2014
[Studies on the microwave leakage of the interphone]
Huan-Ying Li1, Dong-Hui Zhang, Jin-Ming Lin
1Guangdong Prevention & Treatment Center for Occupational Disease, Guangzhou 510300, China.
Objective:
To assay and study the microwave leakage of 4 types of interphones.
Methods:
The radiation intensities of four types of 199 interphones were determined by the microwave leakage measure instrument of model ML-91 made in China.
Results:
The average intensities of microwave leakage at a distance of 5 cm from aerial part and other parts of interphones during launching [(1 316.0 +/- 144.3), (971.0 +/- 131.6) microW/cm(2) respectively] were significantly higher than during waiting [(14.4 +/- 5.3), (13.2 +/- 4.9) microW/cm(2) respectively] (P < 0.01). The average intensities of microwave leakage at a distance of 50 cm from different parts were (357.3 +/- 27.8) microW/cm(2). The daily average intensity of microwave leakage to which the head, chest and abdomen exposed was (945.5 +/- 447.1) microW.h/cm(2) in total, that exceeded the hygienic standard of microwave in China (400 microW.h/cm(2)), during the normal communication by interphones.
Conclusion:
The microwave leakage was higher during launching than during waiting, and was the highest at the aerial part of the interphones. The microwave radiation of most interphones was higher than the current national standard. It may lead to potential effects on the owner of interphone, so protection against it should be made.