A combination atmospheric pressure LC/MS:GC/MS ion source: advantages of dual AP-LC/MS:GC/MS instrumentation
Charles N McEwen1, Richard G McKay
1Central Research & Development Department, DuPont Corporate Center for Analytical Sciences, PO Box 80228, Wilmington, DE 19880-0228, USA. charles.n.mcewen@usa.dupont.com
Abstract:
Modification of commercial LC/MS instrumentation to allow both atmospheric pressure (AP) LC/MS and GC/MS is described. Advantages of this additional capability versus LC/MS alone include higher chromatographic resolution in the GC versus LC mode, greater peak capacity for complex mixture analysis, higher sensitivity for a variety of volatile compounds, and the ability to observe compounds of low polarity that are not readily observed in LC/MS. Advantages over conventional GC/MS include the ability to use higher carrier gas flow and shorter columns for passing less volatile materials through the gas chromatograph, selective ionization, and rapid switching between positive and negative ion modes. Other advantages include application of the enhanced capabilities of LC/MS instrumentation to GC/MS analyses such as cone voltage fragmentation, MS(n), high mass resolution, and accurate mass measurement. Limitations of APGC/MS include the inability to observe saturated hydrocarbon and certain other highly nonpolar compounds and less odd-electron fragmentation for computer aided library searching. For some analyses, the limitation related to ionization of highly nonpolar compounds is advantageous, as is the simplified mass spectrum and easy molecular weight identification that results from less fragmentation observed in the AP ionization mode.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Instrumentation