Detection of nicotinic receptor ligands with a light addressable potentiometric sensor

K R Rogers1, J C Fernando, R G Thompson

  • 1Department of Pharmacology and Experimental Therapeutics, University of Maryland, School of Medicine, Baltimore 21201.

Related Concept Videos

Ligand-gated Ion Channels01:19

Ligand-gated Ion Channels

Ligand-gated ion channels are transmembrane proteins with a channel for ions to pass through and a binding site for a ligand. The channel opens only when a ligand attaches to the binding site.
Three Subfamilies of Ligand-gated Ion Channels
Ligand-gated ion channels fall into three subfamilies. The 'Cys-loop' includes the nicotinic acetylcholine receptors, γ-aminobutyric acid (GABA), glycine, and 5-hydroxytryptamine receptors. The second one is the 'Pore-loop' channels that include the...
Ligand-Gated Ion Channel Receptor: Gating Mechanism01:30

Ligand-Gated Ion Channel Receptor: Gating Mechanism

Ligand-gated ion channels are transmembrane proteins that play a vital role in intercellular communication and functions of the nervous system. They allow the influx of ions across the membrane once the neurotransmitter binds, allowing the subsequent transmission of electrical excitation across the neurons. Other ligand-gated ion channels, like the γ-aminobutyric acid (GABA) receptor, permit anions like chloride into the cells on the binding of the GABA molecule. Their entry into the cell...
Cholinergic Receptors: Nicotinic01:15

Cholinergic Receptors: Nicotinic

Nicotinic receptors are ligand-gated ion channels that are activated by acetylcholine and nicotine. Upon activation, they cause a rapid increase in the permeability of cells to K+, Na+, and Ca2+, followed by depolarization and excitation. They are in the autonomic ganglia, skeletal neuromuscular junction, CNS, and adrenal medulla.
There are two types of nicotinic receptors: neuromuscular (NM/NM/N1) and neuronal (NN/NN/N2). The two families differ based on their location and selectivity to...
Potentiometry: Overview01:06

Potentiometry: Overview

Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as the...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...