Related Experiment Video
Updated: Aug 13, 2026

07:44
A Porcine Model of Acute Autologous Pulmonary Embolism
Published on: September 6, 2024
Intra-aortic filtration: capturing particulate emboli during aortic cross-clamping
Jan T Christenson1, Dominique L Vala, Marc Licker
1Department of Cardiovascular Surgery, University Hospital of Geneva, 24 rue Micheli-duCrest, CH-1211 Geneva 14, Switzerland. jan.christenson@hcuge.ch
Texas Heart Institute Journal
|January 25, 2006
Summary
Intra-aortic filters capture embolic particles during cardiac surgery. Applying filters before aortic cross-clamping and declamping significantly reduces embolic complications, enhancing patient safety.
Area of Science:
- Cardiovascular Surgery
- Biomedical Engineering
- Embolism Research
Background:
- Particulate emboli are a significant cause of complications following cardiac surgery.
- Intra-aortic filters used during aortic declamping are effective in reducing embolic events.
- Aortic cross-clamping itself poses a risk of embolism.
Purpose of the Study:
- To quantify particulate emboli released during aortic cross-clamping and declamping.
- To evaluate the efficacy of intra-aortic filters at both surgical stages.
- To assess the safety of using intra-aortic filters before aortic cross-clamping.
Main Methods:
- 15 consecutive cardiac procedures utilizing cardiopulmonary bypass were studied.
- Intra-aortic filters (Edwards EMBOL-X Slim Protection System) were deployed pre-cross-clamping (Filter A) and pre-declamping (Filter B).
- Histopathologic examination of captured particles was performed by an independent institution.
Main Results:
- All filters captured particulate emboli, irrespective of atherosclerotic disease severity.
- Filter A (pre-cross-clamping) captured significantly more particles (mean 70) than Filter B (pre-declamping, mean 6.7).
- Microscopy confirmed the presence of atheroma or fibrous cap material in 10 of 15 filters; no filter-related complications occurred.
Conclusions:
- Aortic cross-clamping is a critical period for particulate emboli release.
- Employing intra-aortic filtration before both aortic cross-clamping and declamping offers optimal protection against embolic complications.