Related Experiment Video
Updated: Jul 20, 2026

Nanofibrillar Basement Membrane Mimic Made of Recombinant Functionalized Spider Silk in Custom-Made Tissue Culture Inserts
Published on: November 1, 2024
Regenerated spider silk as a new biomaterial for MEMS
Jiamei Bai1, Tim Ma, Winnie Chu
1Department of Mechanical Engineering, 6250 Applied Science Lane, The University of British Columbia, Vancouver, BC, V6T 1Z4, Canada.
Abstract:
Spider drag-line silk is introduced for the first time as a new biomaterial for Micro-Electro-Mechanical Systems (MEMS). The tasks accomplished in this paper were focused on mechanical characterization of regenerated spider silk under two conditions: (1) spin-coated thin film formed onto a silicon substrate; and (2) formation of a free-standing microbridge (800 x 800 x 40 microm3) obtained by a surface micromachining process. Micromechanical tests using a nano indentation machine showed the spider silk film having an elastic modulus of 7.3 GPa, a loss tangent of 0.044 and an UTS (Ultimate Tensile Strength) of 85.1 MPa.