Related Experiment Video
Updated: Jul 17, 2026

Quantitative Measure of Lung Structure and Function Obtained from Hyperpolarized Xenon Spectroscopy
Published on: November 10, 2023
Influence of reduced air pressure methods on dye penetration in standardized voids
Gianluca Plotino1, Nicola M Grande, Nicola Manzulli
1Department of Endodontics, Catholic University of Sacred Heart, Rome, Italy. gplotino@fastwebnet.it
Objective:
The objective of this study was to evaluate the influence of the moment when reduced pressure is applied on dye penetration patterns.
Study Design:
Nine hundred and sixty glass capillary tubes of different inner diameter (0.3 mm and 0.8 mm), divided into 48 groups, were submerged into dye in 3 different positions (horizontally, opening upwards, and opening downwards) under different vacuum conditions (passive, 5 kPa, 35 kPa, 70 kPa reduced pressure). When reduced pressure was applied half of the groups were submerged into dye before and half of the groups after the application of reduced pressure. Linear dye penetration was measured. Univariate analysis was performed with Mann-Whitney U test and Kruskal-Wallis test to select variables to be included in the regression model. A multiple logistic regression analysis with backward elimination was performed to assess the influence of different covariates on linear dye penetration.
Results:
The multivariate linear regression showed that the moment of vacuuming had the greatest positive effect on linear dye penetration value (beta = 10.6, P < .0001). Also the level of pressure reduction had a positive effect on the outcome variable (beta = 0.2, P < .0001) while the vertical positioning of the tubes has negatively affected the outcome variable both for the open end upside (beta = -1.01, P = .024) and the open end downside (beta = -1.05, P = .019). Diameter of the tubes (P = .442) and immersion time (P = .727) had no effect on the outcome of linear dye penetration.
Conclusions:
Even minimum air pressure reduction applied before immersion of the specimens allowed the dye to extensively penetrate the voids.
More Related Videos
13:50Improved Methodology for Liquid Delivery to the Mouse Lung: Intubation using a Consumer Otoscope
Published on: June 17, 2025
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Urodynamic Studies: Uroflowmetry
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...