Patient radiation doses from adult and pediatric CT
1Department of Radiology, SUNY Upstate Medical University, 750 E Adams St., Syracuse, NY 13210-2306, USA. hudaw@upstate.edu
Objective:
The purpose of our study was to determine typical organ doses, and the corresponding effective doses, to adult and pediatric patients undergoing a single CT examination.
Materials And Methods:
Heads, chests, and abdomens of patients ranging from neonates to oversized adults (120 kg) were modeled as uniform cylinders of water. Monte Carlo dosimetry data were used to obtain average doses in the directly irradiated region. Dosimetry data were used to compute the total energy imparted, which was converted into the corresponding effective dose using patient-size-dependent effective-dose-per-unit-energy-imparted coefficients. Representative patient doses were obtained for scanning protocols that take into account the size of the patient being scanned by typical MDCT scanners.
Results:
Relative to CT scanners from the early 1990s, present-day MDCT scanners result in doses that are approximately 1.5 and approximately 1.7 higher per unit mAs in head and body phantoms, respectively. Organ absorbed doses in head CT scans increase from approximately 30 mGy in newborns to approximately 40 mGy in adults. Patients weighing less than approximately 20 kg receive body organ absorbed doses of approximately 7 mGy, which is a factor of 2 less than for normal-sized (70-kg) adults. Adult head CT effective doses are approximately 0.9 mSv, four times less than those for the neonate. Effective doses for neonates undergoing body CT are approximately 2.5 mSv, whereas those for normal-sized adults are approximately 3.5 mSv.
Conclusion:
Representative organ absorbed doses in CT are substantially lower than threshold doses for the induction of deterministic effects, and effective doses are comparable to annual doses from natural background radiation.
Related Concept Videos
Drug Dosing: Infants and Children
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Pharmacokinetics in Pediatric Patients: Drug Excretion
Imaging Studies III: Computed Tomography
Pharmacokinetics in Pediatric Patients: Drug Distribution