A magnetically driven PDMS peristaltic micropump.

Tingrui Pan1, Eleanor Kai, Matthew Stay

  • 1Dept. of Electr. & Comput. Eng., Minnesota Univ., Minneapolis, MN, USA.

Conference Proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
|February 3, 2007
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Multimodal Information Fusion for Control of Rehabilitation Robots in Motor Dysfunction: A Review.

Bioengineering (Basel, Switzerland)·2026
Same author

Human PSC-derived sinoatrial node-cardiac plexus assembloids model innervation-associated maturation of pacemaker systems.

Cell stem cell·2026
Same author

Single-parameter programmed thermomechanical actuation via 3D-printed helical director fields in liquid crystal elastomers.

Nature communications·2026
Same author

Artificial Nanochannel-Mediated Ionic Transmembrane Potential for Adaptive Neuromorphic Tactile Perception.

ACS nano·2026
Same author

Deterministic Evolution of Aptamers via a Microfluidic-Integrated Robotic Platform Using Complex Exosomes as Targets.

ACS nano·2026
Same author

A Perspective on Non-Invasive Blood Pressure Monitoring: Bridging Emerging Principles, Enabling Technologies and Extended Applications.

IEEE reviews in biomedical engineering·2026
Same journal

Highly Articulated Robotic Probe for Minimally Invasive Surgery.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2010
Same journal

Combined peripheral and cortical neural stimulation in motor neurorehabilitation.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2008
Same journal

Embedded assessment algorithms within home-based cognitive computer game exercises for elders.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2008
Same journal

Digital signal processing of the wideband external pulse recorded during cuff deflation: a new way to measure blood pressure.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2008
Same journal

Immune cells detection of the in vivo rejecting heart in USPIO-enhanced magnetic resonance imaging.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2008
Same journal

wHospital: a web-based application with digital signature for drugs dispensing management.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2007
See all related articles

We developed a low-cost polydimethylsiloxane (PDMS) peristaltic micropump using magnetic actuation. This robust device achieves a flow rate of 24 µL/min with low power consumption, suitable for microfluidic applications.

Area of Science:

  • Microfluidics
  • Biomedical Engineering
  • Materials Science

Background:

  • Micropumps are essential for precise fluid handling in microfluidic devices.
  • Existing micropumps often face challenges with cost, complexity, or power consumption.
  • Developing low-cost, efficient micropumps is crucial for advancing lab-on-a-chip technologies.

Purpose of the Study:

  • To design and fabricate a robust, low-cost peristaltic micropump using polydimethylsiloxane (PDMS).
  • To implement a magnetic actuation system for generating peristaltic motion.
  • To evaluate the performance characteristics of the developed micropump.

Main Methods:

  • Fabrication using soft molding and bonding of three PDMS layers.
  • Integration of a microchannel, actuation membrane, and magnetic rods (Ni-plated-NdFeB).

Related Experiment Videos

  • Utilizing a DC motor with mounted magnets to drive the actuation membrane magnetically.
  • Main Results:

    • Demonstrated a maximum pumping rate of approximately 24 µL/min at 1700 rpm.
    • Achieved low power consumption of 11 mW.
    • Preliminary numerical analysis confirmed characteristic membrane deflection and fluid flow patterns.

    Conclusions:

    • The developed PDMS peristaltic micropump offers a robust and cost-effective solution for microfluidic fluid transport.
    • Magnetic actuation provides an efficient mechanism for generating the peristaltic waveform.
    • The micropump shows potential for various microfluidic applications requiring precise and low-power fluid delivery.