Related Experiment Video
Updated: Jul 15, 2026

Development of a Noninvasive, Laser-Assisted Experimental Model of Corneal Endothelial Cell Loss
Published on: April 24, 2020
Laser ablation threshold dependence on pulse duration for fused silica and corneal tissues: experiments and modeling
Dominic Giguère1, Gilles Olivié, François Vidal
1Institut National de la Recherche Scientifique-Energie, Matériaux et Télécommunications, Varennes, Quebec, Canada.
Abstract:
The surface ablation threshold fluence of fused silica and two porcine cornea layers, the epithelium and the stroma, is characterized as a function of the laser pulse duration in the range of 100 fs-5 ps for a wavelength of 800 nm (Ti:sapphire laser system). The plateaulike region observed between 100 fs and 1 ps for the corneal layers indicates that for use in laser surgery, laser pulse durations chosen within this range should be practically equivalent. Our model predicts that the ablation threshold will decrease rapidly for pulse durations in the low end of the femtosecond regime.