Titration efficacy of two auto-adjustable continuous positive airway pressure devices using different flow
Katrien B Hertegonne1, Bart Rombaut, Philippe Houtmeyers
1Department of Respiratory Diseases, Ghent University Hospital, Ghent, Belgium. Katrien.Hertegonne@UGent.be
Background:
Auto-adjustable continuous positive airway pressure devices are widely used in titration procedures to determine therapeutic pressure levels in obstructive sleep apnea patients. However, differences in operational characteristics may influence the effect on the apnea-hypopnea index (AHI).
Objectives:
We compared the titration performance of two devices based on detection of inspiratory flow limitation, i.e. the Respironics REMstar Auto (RR) and the ResMed Spirit (RS).
Methods:
Fifty obstructive sleep apnea patients were recruited for a double-blind randomized crossover trial. Both devices were employed overnight by means of split-night polysomnography. The primary outcome was the AHI. Secondary outcome measures were the snoring index, pressure profiles and subjective appraisal of sleep quality assessed the morning after the sleep study. The Wilcoxon signed rank test for matched pairs was applied to assess differences between treatment conditions.
Results:
No significant differences were found in sleep parameters, subjective sleep quality and snoring index. The use of the RR was associated with a significantly lower AHI in comparison with the RS [mean (SD) 6.9 (11.6)/h vs. 9.4 (9.2)/h, p = 0.004]. This result was obtained at significantly lower pressure levels [P95 9.2 (2.3) cm H(2)O vs. 10.2 (1.5) cm H(2)O, p = 0.001].
Conclusion:
While the RR provided a lower AHI than the RS at lower pressure levels, it could not be assessed whether this difference was relevant for clinical outcomes. However, this face-to-face comparison of Auto-adjustable continuous positive airway pressure devices seems useful for the assessment of titration efficacy.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Inhaled Medications