Related Experiment Video
Updated: Jul 10, 2026

Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Differential electroencephalographic response to tracheal intubation between young and elderly during isoflurane and
T Matsuura1, Y Oda, K Ikeshita
1Department of Anesthesiology and Intensive Care Medicine, Graduate School of Medicine, Osaka City University, 1-5-7 Asahimachi, Abeno-ku, Osaka 545-8586, Japan.
Background:
Age-associated differences in the electroencephalographic (EEG) response to noxious stimuli with the presence of nitrous oxide (N(2)O) are unknown. We compared the EEG response with tracheal intubation between young and elderly.
Methods:
Sixty young (<40 yr) and elderly (>70 yr) patients were randomly allocated to one of the four groups. Anaesthesia was induced with 66% N(2)O and isoflurane in oxygen (Young-isoflurane and Elderly-isoflurane groups) or 66% N(2)O and sevoflurane in oxygen (Young-sevoflurane and Elderly-sevoflurane groups). Inhaled isoflurane and sevoflurane concentrations were gradually increased and the end-tidal concentrations were maintained at 1.1% and 1.7%, respectively. Tracheal intubation was performed 12 min after induction of anaesthesia.
Results:
There were significant differences in the overall changes in bispectral index (BIS) and 95% spectral edge frequency (SEF95) between young and elderly (P<0.001 for both), but not between patients receiving isoflurane and sevoflurane (P=0.4 and 0.3, respectively). Both BIS and SEF95 were significantly decreased after tracheal intubation in Young-isoflurane and Young-sevoflurane groups (P<0.05 for all). In sharp contrast, BIS and SEF95 remained unchanged in Elderly-isoflurane and Elderly-sevoflurane groups (P>0.7 for all). These results suggest that both BIS and SEF95 significantly decreased, despite the presence of increased sympathetic activity after tracheal intubation in young patients.
Conclusions:
A significant difference was detected in EEG response to tracheal intubation between young and elderly. BIS does not reflect the depth of anaesthesia after tracheal intubation during anaesthesia with isoflurane or sevoflurane with 66% of N(2)O in young patients.
Related Concept Videos
Inhalational Anesthetics: Overview
Stages of General Anesthesia
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Local Anesthetics: Differential Sensitivity of Nerve Fibers