Evaluation of a commercial radiochromatography module as an arterial blood activity monitor
Related Experiment Video
Updated: Jul 8, 2026

Measurement of Myocardial Lactate Production for Diagnosis of Coronary Microvascular Spasm
Published on: September 17, 2021
C M Laymon1, D Sashin, J P Carney
1University of Pittsburgh, Department of Radiology, Pittsburgh, PA 15213, USA. CML14@pitt.edu
Abstract:
Input functions required for positron emission tomography (PET) tracer kinetic modeling are often obtained from arterial blood. In some situations, using short-lived radiotracers, e.g. [(15)O]water, rapid sample handling is required. A method used at several facilities is to pump blood through a detector system at a constant rate. We investigate the suitability of a commercial radiochromatography module (IN/US Posi-RAM) for this new use. The Posi-RAM consists of two 2.5 cm (length) x 2.5 cm (diameter) cylindrical bismuth germanate (BGO) detectors that can operate in coincidence mode. Arterial blood is transported through the system via a length of tubing with flow rate controlled by a peristalsis pump. A custom-counting loop and support frame were designed for the Posi-RAM for PET studies. System sensitivity was determined to be 1.1 x 10(4) cps/(MBq ml(-1)). Dead time as a function of count-rate was found to be less than 1% for concentrations below 3.5 MBq ml(-1), a range encompassing all human-study values. In a human study, the performance of the device was found to be similar to that of the facility's current blood monitor (Siemens Fluid Monitor). We conclude that the Posi-RAM has the necessary sensitivity and count-rate capabilities to be used as a real-time blood activity monitor.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)