Metallic artifacts in MRI caused by dental alloys and magnetic keeper
Darline Destine1, Hiroshi Mizutani, Yoshimasa Igarashi
1Department of Removable Prosthodontics, Masticatory Function Rehabilitation, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University, Tokyo, Japan. mztn.rpro@tmd.ac.jp
Purpose:
To evaluate the artifacts generated by crownshaped dental alloys and a magnetic keeper quantitatively by analyzing digital MRI data.
Methods:
One pre-fabricated magnetic keeper and four clinical dental alloys (gold-silver-palladium, casting gold alloy Type 3, cobalt-chromium, gold porcelain alloy) were selected. Twenty metal crowns and 5 magnetic keepers were analyzed. The samples were placed in an acrylic phantom (150 mmx150 mmx150 mm) filled with agar, and then placed in the MRI apparatus. Various image slices were selected from the center (0 mm) to 70 mm at steps of 5 mm. The distribution of the signal intensity in the region of interest was calculated using ImageJ software and the mean coefficient of variation of each specimen was obtained. Statistical analysis was performed by Dunnett's test (p<0.05).
Results:
Compared to the resin control, cobalt-chromium showed significantly greater signal intensity up to 40 mm in coronal T2-WI images and up to 70 mm in axial T1-WI images for the magnetic keeper. The signal intensities of gold-silver-palladium and casting gold alloy Type 3 were not significantly different from that of the control. The signal intensity of gold porcelain alloy was significantly different from that of the control at 0 mm and 5 mm in coronal T1,T2-WI and in sagittal T1-WI at 0 mm.
Conclusions:
The artifacts generated by the magnetic keeper and the cobalt-chromium crown when they are used in a second molar can disturb the MR images of the temporomandibular joint.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Ferromagnetism
Diamagnetism
Diamagnetism was discovered by Anton Brugmans in 1778 when he observed that bismuth gets repelled by magnetic fields, thus theorizing that diamagnets get repelled by magnets.
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...