Aortoduodenal fistula and aortic aneurysm secondary to biliary stent-induced retroperitoneal perforation
Tae-Hoon Lee1, Do-Hyun Park, Ji-Young Park
1Department of Internal Medicine, University of Ulsan College of Medicine, Asan Medical Center, Songpagu, Seoul 138-736, South Korea.
Abstract:
Duodenal perforations caused by biliary prostheses are not uncommon, and they are potentially life threatening and require immediate treatment. We describe an unusual case of aortic aneurysm and rupture which occurred after retroperitoneal aortoduodenal fistula formation as a rare complication caused by biliary metallic stent-related duodenal perforation. To our knowledge, this is the first report describing a lethal complication of a bleeding, aortoduodenal fistula and caused by biliary metallic stent-induced perforation.
Related Concept Videos
Aneurysm III: Interprofessional Care
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus.
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm I: Introduction
Chronic Bowel Disorders: Introduction
Irritable Bowel Syndrome (IBS) is a common disorder affecting the gastrointestinal tract. The distinctive feature is recurrent abdominal pain associated with altered bowel movements, manifesting as constipation, diarrhea, or fluctuating between both. The...