Aortic valve replacement with omniscience and omnicarbon valves.
T Kazui1, O Yamada, M Yamagishi
1Department of Thoracic and Cardiovascular Surgery, Sapporo Medical College and Hospital, Japan.
The Annals of Thoracic Surgery
|August 1, 1991
Summary
The Omnicarbon (O-C) valve demonstrated a significantly lower rate of valve-related complications compared to the Omniscience (O-S) valve in aortic valve replacement surgeries. This suggests improved long-term outcomes for patients receiving the O-C valve.
Area of Science:
- Cardiac Surgery
- Biomaterials Science
- Clinical Outcomes Research
Background:
- Aortic valve replacement is a critical procedure for managing severe aortic valve disease.
- Bioprosthetic heart valves are widely used, with varying clinical performance.
- The Omniscience (O-S) and Omnicarbon (O-C) valves are mechanical prostheses used in aortic valve replacement.
Purpose of the Study:
- To compare the clinical outcomes of aortic valve replacement using the Omniscience (O-S) valve versus the Omnicarbon (O-C) valve.
- To evaluate survival rates, event-free rates for thromboembolic complications, and valve-related complications between the two valve types.
Main Methods:
- Retrospective analysis of 100 aortic valve replacements with O-S valves (1980-1985) and 100 with O-C valves (1985-1989).
- Inclusion of concomitant procedures, such as mitral valve replacement, in 63 O-S and 67 O-C patients.
- Cumulative follow-up of 559 patient-years for O-S and 273 patient-years for O-C, assessing 4-year actuarial rates.
Main Results:
- Overall 4-year survival rates were 82% (O-S) and 89.5% (O-C); for isolated aortic valve replacement, 82.9% (O-S) and 91.9% (O-C).
- 4-year event-free rates for thromboembolism were 88.8% (O-S) and 94.4% (O-C) overall, and 89.2% (O-S) and 95.9% (O-C) for isolated procedures.
- The overall rate of valve-related complications was significantly lower in the O-C group (89.3%) compared to the O-S group (78.8%) (p < 0.05).
Conclusions:
- The Omnicarbon (O-C) valve demonstrated a superior valve-related complication profile compared to the Omniscience (O-S) valve.
- Patients undergoing aortic valve replacement with the O-C valve experienced better outcomes regarding valve-related complications.
- These findings suggest that the O-C valve may be a preferable choice for aortic valve replacement due to its improved safety profile.