Related Experiment Video
Updated: Jul 2, 2026

14:16
Fluorescence detection methods for microfluidic droplet platforms
Published on: December 10, 2011
Phase fluorometer for measurement of picosecond processes.
1Institut für Physikalische Chemie der Universität Stuttgart, Pfaffenwaldring 55, Stuttgart 80, West Germany.
The Review of Scientific Instruments
|May 1, 1978
Summary
This study explores time-dependent fluorescence using a variable-frequency phase fluorometer. Its high 500 MHz cutoff frequency achieves precise time resolution of approximately 1 picosecond.
Area of Science:
- Physical Chemistry
- Spectroscopy
Background:
- Time-dependent fluorescence is crucial for understanding molecular dynamics.
- Phase fluorometry is a key technique for studying fluorescence lifetimes.
Purpose of the Study:
- To investigate time-dependent fluorescence processes.
- To evaluate the capabilities of a variable-frequency phase fluorometer.
Main Methods:
- Utilized a phase fluorometer with variable frequency.
- Employed a high cutoff frequency of 500 MHz.
Main Results:
- Achieved a time-resolving power of approximately 1 picosecond.
- Demonstrated the effectiveness of the instrument for time-resolved fluorescence studies.
Conclusions:
- Variable-frequency phase fluorometry enables high-resolution studies of fluorescence dynamics.
- The instrument's performance is suitable for picosecond-level investigations.
Related Concept Videos
Fluorescence and Phosphorescence: Instrumentation
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Protein Dynamics in Living Cells
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Super-resolution Fluorescence Microscopy
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.