Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Paced respiration with end-expiration technique offers superior BOLD signal repeatability for breath-hold studies
1Medical Research Council, Cognition and Brain Sciences Unit, Cambridge, UK. amy.scouten@mrc-cbu.cam.ac.uk
Abstract:
As a simple, non-invasive method of blood oxygenation level-dependent (BOLD) signal calibration, the breath-hold task offers considerable potential for the quantification of neuronal activity from functional magnetic resonance imaging (fMRI) measurements. With an aim to improve the precision of this calibration method, the impact of respiratory rate control on the BOLD signal achieved with the breath-hold task was investigated. In addition to self-paced breathing, three different computer-paced breathing rates were imposed during the periods between end-expiration breath-hold blocks. The resulting BOLD signal timecourses and statistical activation maps were compared in eleven healthy human subjects. Results indicate that computer-paced respiration produces a larger peak BOLD signal increase with breath-hold than self-paced breathing, in addition to lower variability between trials. This is due to the more significant post-breath-hold signal undershoot present in self-paced runs, a characteristic which confounds the definition of baseline and is difficult to accurately model. Interestingly, the specific respiratory rate imposed between breath-hold periods generally does not have a statistically significant impact on the BOLD signal change. This result can be explained by previous reports of humans adjusting their inhalation depth to compensate for changes in rate, with the end-goal of maintaining homeostatic ventilation. The advantage of using end-expiration relative to end-inspiration breath-hold is apparent in view of the high repeatability of the BOLD signal in the present study, which does not suffer from the previously reported high variability associated with uncontrolled inspiration depth when using the end-inspiration technique.
More Related Videos
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Mechanism of Breathing II: Expiration
Expiration, or exhaling, is a complex physiological process that begins as the inspiratory muscles begin to relax. This relaxation triggers a series of events that epitomize the efficiency of the respiratory system.
Mechanism of Expiration: