Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
Atomic Nuclei: Nuclear Relaxation Processes01:23

Atomic Nuclei: Nuclear Relaxation Processes

In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis,  the precessing magnetic moments are randomly oriented around the z-axis. This...
Atomic Nuclei: Nuclear Spin State Overview01:03

Atomic Nuclei: Nuclear Spin State Overview

NMR-active nuclei have energy levels called 'spin states' that are associated with the orientations of their nuclear magnetic moments. In the absence of a magnetic field, the nuclear magnetic moments are randomly oriented, and the spin states are degenerate. When an external magnetic field is applied, the spin states have only 2 + 1 orientations available to them. A proton with = ½ has two available orientations. Similarly, for a quadrupolar nucleus with a nuclear spin value of one, the...
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
Magnetic Field Lines01:19

Magnetic Field Lines

The representation of magnetic fields by magnetic field lines is very useful in visualizing the strength and direction of the magnetic field. Each of the magnetic field lines forms a closed loop. The field lines emerge from the north pole (N), loop around to the south pole (S), and continue through the bar magnet back to the north pole.
Magnetic field lines follow several hard-and-fast rules:
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current01:14

Diamagnetic Shielding of Nuclei: Local Diamagnetic Current

An applied magnetic field causes the electrons present in the molecule to circulate, setting up a local diamagnetic current within the molecule. The local diamagnetic current arising from circulating sigma-bonding electrons induces a magnetic field, Blocal that opposes the applied magnetic field, B0. The effective magnetic field experienced by these nuclei is given by the difference between the applied and local magnetic fields in a phenomenon called local diamagnetic shielding. Essentially,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Probing the Quantum Interference between Singly and Doubly Resonant Top-Quark Production in pp Collisions at sqrt[s]=13  TeV with the ATLAS Detector.

Physical review letters·2018
Same author

Model-free classification of X-ray scattering signals applied to image segmentation.

Journal of applied crystallography·2018
Same author

Measurement of the Soft-Drop Jet Mass in pp Collisions at sqrt[s]=13  TeV with the ATLAS Detector.

Physical review letters·2018
Same author

Measurement of jet fragmentation in Pb+Pb and

The European physical journal. C, Particles and fields·2018
Same author

Precision measurement and interpretation of inclusive

The European physical journal. C, Particles and fields·2018
Same author

Search for new phenomena using the invariant mass distribution of same-flavour opposite-sign dilepton pairs in events with missing transverse momentum in

The European physical journal. C, Particles and fields·2018
Same journal

Erratum: Bacterial Turbulence at Compressible Fluid Interfaces [Phys. Rev. Lett. 136, 138301 (2026)].

Physical review letters·2026
Same journal

Unveiling Light-Quark Yukawa Flavor Structure via Dihadron Fragmentation at Lepton Colliders.

Physical review letters·2026
Same journal

Adaptable Route to Fast Coherent State Transport via Bang-Bang-Bang Protocols.

Physical review letters·2026
Same journal

Topological Transition and Emergence of Elasticity of Dislocation in Skyrmion Lattice: Beyond Kittel's Magnetic-Polar Analogy.

Physical review letters·2026
Same journal

Pound-Drever-Hall Method for Superconducting-Qubit Readout.

Physical review letters·2026
Same journal

Coupling a ^{73}Ge Nuclear Spin to an Electrostatically Defined Quantum Dot in Silicon.

Physical review letters·2026
See all related articles

Related Experiment Video

Updated: Jul 2, 2026

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
07:42

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

Published on: July 20, 2022

Neutron decoherence imaging for visualizing bulk magnetic domain structures.

C Grünzweig1, C David, O Bunk

  • 1Paul Scherrer Institut, CH-5232 Villigen PSI, Switzerland.

Physical Review Letters
|September 4, 2008
PubMed
Summary
This summary is machine-generated.

A new neutron imaging method visualizes internal magnetic domains by measuring changes in neutron wave front coherence. This technique offers a versatile way to study magnetic structures in various materials and conditions.

More Related Videos

Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
09:43

Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement

Published on: November 7, 2017

Related Experiment Videos

Last Updated: Jul 2, 2026

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
07:42

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

Published on: July 20, 2022

Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
09:43

Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement

Published on: November 7, 2017

Area of Science:

  • Materials Science
  • Condensed Matter Physics
  • Neutron Optics

Background:

  • Visualizing internal bulk magnetic domain structures is challenging with existing techniques.
  • Understanding magnetic domain behavior is crucial for materials development.

Purpose of the Study:

  • Introduce a novel neutron imaging method to visualize internal magnetic domain structures.
  • Demonstrate the technique's applicability to diverse specimens and external conditions.

Main Methods:

  • Utilize small-angle neutron scattering at magnetic domain walls to alter neutron wave front spatial coherence.
  • Develop a neutron imaging technique based on changes in spatial coherence.

Main Results:

  • Successfully visualized internal bulk magnetic domain structures.
  • Demonstrated the method's transferability to various specimens.
  • Showed the technique's extendibility to 3D imaging.
  • Confirmed suitability for in-situ studies under external magnetic fields, temperature, or pressure.

Conclusions:

  • The novel neutron imaging method effectively visualizes internal magnetic domains.
  • This technique provides a versatile and powerful tool for magnetic materials research.
  • The method is well-suited for investigating materials under varying external parameters.