Summary
Polymer locking clips offer a safe alternative to staplers for laparoscopic donor nephrectomy, preserving greater renal vein length without complications. Donor and recipient outcomes remained similar between methods.
Area of Science:
- Minimally Invasive Surgery
- Transplant Surgery
- Surgical Devices
Background:
- Laparoscopic donor nephrectomy is standard for living donor kidney removal.
- ENDO GIA staplers are commonly used for renal vessel division but can reduce graft vascular length and malfunction.
- Alternative vascular control methods are sought to optimize outcomes.
Purpose of the Study:
- To evaluate the safety and efficacy of polymer locking clips for vascular control during laparoscopic donor nephrectomy.
- To compare outcomes using polymer locking clips versus the ENDO GIA stapler.
- To assess the impact on graft vascular length and complications.
Main Methods:
- Eleven laparoscopic donor nephrectomies utilized polymer locking clips for renal artery and vein division.
- Vascular control was achieved with at least two polymer locking clips on the donor side.
- Outcomes were compared to 33 prior cases using the ENDO GIA stapler for renal vein control.
Main Results:
- Operative and warm ischemia times were comparable between the two techniques.
- Polymer locking clips allowed for harvesting of nearly the entire renal vein length.
- No vascular complications or graft loss occurred with polymer locking clips; one stapler malfunction required conversion to open surgery.
Conclusions:
- Polymer locking clips are a safe and effective method for vascular control in laparoscopic donor nephrectomy.
- This technique yields greater renal vessel length compared to stapler devices.