Related Experiment Video
Updated: Jun 27, 2026

Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements
Published on: February 28, 2016
Accurate and quick calibration method for polarization-modulation spectroscopy using an ac-modulated polarizing
Masahito Tanaka1, Kazutoshi Yagi-Watanabe, Fusae Kaneko
1Research Institute of Instrumentation Frontier, National Institute of Advanced Industrial Science and Technology (AIST), Central 2, Umezono 1-1-1, Tsukuba, Ibaraki 305-8568, Japan. masahito-tanaka@aist.go.jp
A new calibration method using an ac-modulated polarizing undulator accurately calibrates vacuum ultraviolet circular dichroism (CD) and linear dichroism (LD) spectra. This technique significantly reduces measurement time and improves spectral accuracy, aiding protein secondary structure analysis.
Area of Science:
- Spectroscopy
- Optical Physics
- Materials Science
Background:
- Accurate calibration is crucial for polarization modulation spectroscopy, especially in the vacuum ultraviolet (VUV) region.
- Established standard samples for VUV circular dichroism (CD) and linear dichroism (LD) calibration are lacking.
- Existing calibration methods can be time-consuming and may not fully account for experimental variations.
Purpose of the Study:
- To propose and validate an accurate calibration method for VUV CD and LD spectroscopy.
- To utilize an ac-modulated polarizing undulator and a multireflection polarimeter for calibration.
- To establish a reliable calibration procedure in the absence of standard samples in the VUV region.
Main Methods:
- An undulator-modulation spectroscopic method was employed using a multireflection polarimeter.
- The polarimeter was treated as a standard sample for calibration.
- Calibration factors were determined for CD and LD spectra across a wide wavelength range (120-230 nm).
Main Results:
- The proposed calibration method was successfully applied to VUV CD and LD spectra at the TERAS storage ring (BL-5B).
- Calibrated spectra showed good agreement with standard spectra above 170 nm (mean differences of ~7% for CD, ~4% for LD).
- Experimental time was significantly reduced from ~1 hour to <10 minutes, allowing observation of storage-ring current dependence.
Conclusions:
- The ac-modulated polarizing undulator method provides accurate calibration for VUV CD and LD spectroscopy.
- This method offers a substantial reduction in experimental time and enhances spectral reliability.
- The technique is applicable to VUV-CD spectra obtained with conventional modulators, facilitating precise protein secondary structure analysis.