Preanalytical and postanalytical variables: the leading causes of diagnostic error in hemostasis?
Emmanuel J Favaloro1, Giuseppe Lippi, Dorothy M Adcock
1Department of Haematology, ICPMR, Westmead Hospital, Westmead, Australia. emmanuel.favaloro@swahs.health.nsw.gov.au
Abstract:
The advent of modern instrumentation, with associated improvements in test reliability, together with appropriate internal quality control and external quality assurance measures, has led to substantial reduction in analytical errors within hemostasis laboratories. Unfortunately, the reporting of incorrect or inappropriate test results still occurs, perhaps even as frequently as in the past. Many of these cases will arise due to a variety of events largely outside the control of the laboratories performing the laboratory tests and primarily comprise preanalytical events related to patient collection and sample processing and postanalytical events related to the reporting and interpretation of test results. The current article provides an overview of these events and provides some suggestions on how they can be minimized or prevented to ensure that the test results the clinician receives actually represent the true clinical status of the patient under investigation rather than just reflecting the status of an (inappropriate) clinical sample received and tested. This article should be of interest to both laboratory scientists working in hemostasis and the clinicians that request such tests. The former, because these are ultimately responsible for the test results they provide to clinicians, and there is a duty of care to provide both accurate and precise results to enable clinicians to manage patients appropriately and to avoid the need to recollect and retest. The latter because unless clinicians gain an appreciation of these issues, they will not be in a position to best manage their patients.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Introduction to Hemostasis
The three phases of hemostasis involve many clotting factors present in plasma and several substances released by platelets and injured tissue cells. It is a fast, localized, and...
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which forms a...