Absolute brightness of fluorescent microspheres

Isaac Finger1, Scott Phillips, Elizabeth Mobley

  • 1Department of Materials Science and Engineering, University of Florida, Gainesville, FL 32611-6400, USA.

Lab on a Chip
|January 22, 2009
PubMed
Summary

The absolute brightness of fluorescent microspheres was measured, providing key data for developing advanced fluorescence detection technologies and smart dust devices.

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Variables Affecting Phosphorescence and Fluorescence01:26

Variables Affecting Phosphorescence and Fluorescence

Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.