Related Experiment Video
Updated: Jun 24, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Automated headspace solid-phase microextraction versus headspace for the analysis of furan in foods by gas
M S Altaki1, F J Santos, M T Galceran
1Departament de Química Analítica, Universitat de Barcelona, Diagonal 647, Barcelona 08028, Spain.
Abstract:
A simple, fast and fully automated method based on headspace solid-phase microextraction coupled on-line with gas chromatography-ion trap mass spectrometry (HS-SPME-GC-ITMS) is proposed for furan determination in foods. The performance of the proposed method was compared to the automated headspace-GC-MS method, proposed by the US Food and Drugs Administration (US FDA), in terms of repeatability, limits of the detection and quantification. Both methods gave similar results for furan determination in selected food samples, although slightly worse precision (RSD%, 9-12%) and higher limits of detection (from 5 to 20 times higher) were obtained by the headspace method. In addition, higher sample throughput in routine furan analysis was obtained using the proposed HS-SPME-GC-ITMS method with isotope dilution than using the US FDA method, which recommends standard addition for quantification. The proposed method provides good precision (RSD% <10%) and low limits of detection, ranging from 0.02 to 0.12 ng g(-1) depending on the sample. The developed HS-SPME-GC-MS method was used to analyse furan in several Spanish food commodities and concentrations ranging from 0.1 ng g(-1) to 1.1 microg g(-1) were found.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...