Related Experiment Video
Updated: Jun 16, 2026

Iridium(III) Luminescent Probe for Detection of the Malarial Protein Biomarker Histidine Rich Protein-II
Published on: July 7, 2015
Lead(II)-induced allosteric G-quadruplex DNAzyme as a colorimetric and chemiluminescence sensor for highly sensitive
Tao Li1, Erkang Wang, Shaojun Dong
1State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin, 130022, People's Republic of China.
Abstract:
The lead ion (Pb(2+)) has been proven to induce a conformational change of K(+)-stabilized G-quadruplex DNAzyme and inhibit the peroxidase-like activity [Li, T.; Wang, E.; Dong, S. J. Am. Chem. Soc. 2009, 131, 15082-15083]. This provides a rationale for utilizing Pb(2+)-induced allosteric G-quadruplex DNAzyme to probe aqueous Pb(2+). Here, we choose a common G-quadruplex DNAzyme named PS2.M to develop a novel Pb(2+) sensor with two detection means: colorimetry and chemiluminescence (CL). In the presence of K(+), PS2.M (with hemin as a cofactor) exhibits a superior DNAzyme activity and effectively catalyzes the H(2)O(2)-mediated oxidation of 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS) or luminol, which results in a color change or generates CL emission. Upon the addition of Pb(2+), K(+)-stabilized PS2.M is induced to convert to the Pb(2+)-stabilized structure with higher stability but lower DNAzyme activity, which is reflected by an obvious increase in DNA melting temperature but a sharp decrease in readout signal. This allows us to utilize PS2.M for quantitative analysis of aqueous Pb(2+) using the ABTS-H(2)O(2) colorimetric system and luminol-H(2)O(2) CL system. In each case, the readout signal is linearly dependent on the logarithm of Pb(2+) concentration within a certain range. Nevertheless, two sensing systems provide different sensitivity for Pb(2+) analysis. With colorimetry, Pb(2+) can be detected at a level of 32 nM (approximately 7 ppb), whereas the detection limit of Pb(2+) is 1 nM (0.2 ppb) when utilizing the CL method. In addition to high sensitivity, the above sensing systems exhibit good selectivity for Pb(2+) over other metal ions. These results demonstrate the facility and effectivity of our introduced DNAzyme-based sensor for quantitative Pb(2+) analysis.
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Photoluminescence: Applications

