Related Experiment Video
Updated: Jun 16, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Innovative radiographic system to improve the sharpness of radiographs: could a phase-shift effect contribute to
Junji Tanaka1, Hiromi Oda, Toshihide Mimura
1Department of Diagnostic Radiology, Saitama Medical University Hospital, Irumagun, Saitama, Japan. jtanaka@saitama-med.ac.jp
Purpose:
The aim of this study was to determine whether a high-resolution digital radiography system that was originally developed for mammography could be used for general radiographic purposes by means of a phantom test.
Materials And Methods:
This system includes an X-ray tube with a smaller focal point than is generally used for general radiography, and a computed radiography (CR) system to provide the highest spatial resolution. The imaging object and CR plate are intentionally separated to capture an edge-enhancing effect that is the result of a phase-shift (phase contrast) of the X-rays.
Results:
This system showed greater sharpness and spatial resolution, as well as an equal level of contrast resolution compared to a conventional X-ray system. The image sharpness in this system appears to be at least partially attributable to an edge-enhancing effect produced by the phase-contrast effect, which occurs when X-rays pass the surfaces of objects.
Conclusion:
This technique may be suitable for clinical use and may contribute to improved image-quality in general radiography.
Related Concept Videos
X-ray Imaging
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...