Related Experiment Video
Updated: Jun 14, 2026

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Single breath-hold assessment of ventricular volumes using 32-channel coil technology and an extracellular contrast
Victoria Parish1, Tarique Hussain, Philip Beerbaum
1Division of Imaging Sciences, NIHR Biomedical Research Centre at Guy's & St Thomas' NHS Foundation Trust, King's College London, London, UK. victoria.parish@kcl.ac.uk
Purpose:
To evaluate the feasibility of a single breath-hold 3D cine balanced steady-state free precession (b-SSFP) sequence after gadolinium diethylenetriamine penta-acetic acid (Gd-DTPA) injection for volumetric cardiac assessment.
Materials And Methods:
Fifteen adult patients routinely referred for cardiac magnetic resonance imaging (MRI) underwent quantitative ventricular volumetry on a clinical 1.5T MR-scanner using a 32-channel cardiac coil. A stack of 2D cine b-SSFP slices covering the ventricles was used as reference, followed by a single breath-hold 3D cine balanced SSFP protocol acquired before and after administration of Gd-DTPA. The acquisition was accelerated using SENSE in both phase encoding directions. Volumetric and contrast-to-noise data for each technique were assessed and compared.
Results:
The 3D cine protocol was accomplished within one breath-hold (mean acquisition time 20 sec; spatial resolution 2.1 x 2.1 x 10 mm; temporal resolution 51 msec). The contrast-to-noise ratio between blood and myocardium was 234 determined for the multiple 2D cine data, and could be increased for the 3D acquisition from 136 (3D precontrast) to 203 (3D postcontrast) after injecting Gd-DTPA. In addition the endocardial definition was significantly improved in postcontrast 3D cine b-SSFP. There was no significant difference for left and right ventricular volumes between standard 2D and 3D postcontrast cine b-SSFP. However, Bland-Altman plots showed greater bias and scatter when comparing 2D with 3D cine b-SSFP without contrast.
Conclusion:
3D cine b-SSFP imaging of the heart using 32 channel coil technology and spatial undersampling allows reliable volumetric assessment within a single breath-hold after application of Gd-DTPA.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Imaging Studies for Cardiovascular System IV: CMRI