Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Relationship between radiographic techniques (kilovolt and milliampere-second) and CTDI(VOL)
Saeed Elojeimy1, Sameer Tipnis, Walter Huda
1Department of Radiology and Radiological Science, 96 Jonathan Lucas Street, MSC 323, Medical University of South Carolina, Charleston, SC 29425-3230, USA.
Abstract:
To investigate the relationship between radiographic techniques (i.e. kilovolt and milliampere-second) and the corresponding volume computed tomography dose index (CTDI(vol)). Data were obtained for CTDI(vol) for head and body phantoms from the ImPACT CT patient dosimetry calculator for 43 scanners from four major vendors of medical imaging equipment (i.e. GE, Philips, Siemens and Toshiba). CTDI(vol) were obtained with the largest X-ray beam width, and using a CT pitch of unity. For each scanner, relative values of CTDI(vol) were also computed as a function of X-ray tube voltage, normalised to unity at 120 kV. The average CTDI(vol) for 43 commercial scanners was 167 + or - 44 microGy (mA s)(-1) for the head phantom and 78 + or - 22 microGy (mA s)(-1) for the body phantom. The 90th percentile CTDI(vol) values are approximately twice the corresponding 10th percentile values for both head and body phantoms. Over the last 20 y, the head phantom CTDI(vol) has increased approximately 50 % and the body phantom CTDI(vol) has increased approximately 90 %. For both, the head phantom and the body phantom, CTDI(vol) is proportional to kilovolt(2.6). CT output must be specified using CTDI(vol) because for a fixed kilovolt and milliampere-second, CT scanner outputs (CTDI(vol)) differ by about a factor of 2. Increasing the X-ray tube voltage from 80 to 140 kV increases CTDI(vol) by about a factor of 4.
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Voltammetric Techniques: Cyclic Voltammetry
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Voltmeter
An ideal voltmeter would have infinite resistance, so connecting it between two points in a circuit would not alter any of the currents. Real voltmeters always have finite...
Imaging Studies for Cardiovascular System V: CT
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Linear-Scan (E vs Time)