Fast polymer fingerprinting using flowing afterglow atmospheric pressure glow discharge mass spectrometry
Matthias C Jecklin1, Gerardo Gamez, Renato Zenobi
1Department of Chemistry and Applied Biosciences, ETH Zürich, CH-8093 Zürich, Switzerland.
Abstract:
Flowing afterglow atmospheric pressure glow discharge mass spectrometry (FA-APGD-MS) was used to interrogate different polymer species such as biopolymers, synthetic homo- and co-polymers. The main advantages of FA-APGD-MS for polymer samples include speed (<30 s per sample) and analysis at atmospheric pressures. Moreover, there are essentially no restrictions as to the kind of polymer sample that can be analyzed because FA-APGD-MS can deal with liquid and solid (soluble or insoluble) bulk polymers and granulates, irrespective of their conductivity, without requiring any sample preparation prior to analysis. We will discuss the mechanism of ion formation as well as the limitation of the accessible mass range (m/z < 500) in view of what type of information can be gained from the mass spectra obtained. Monomer units and some fragments were detected for homopolymers, e.g.cis-polyisoprene (IR), poly(ethylene glycol) (PEG), poly(ethylene terephthalate) (PET), which allowed identification of the polymer composition. The mass spectra obtained were further processed using principal component analysis (PCA) for a better visualization and assessing of mass-spectral reproducibility. Combination with PCA even allowed differentiation of pectin, amylopectin, and cellulose, chemically very similar polysaccharides whose characteristic differences lie in the nature of the glycosidic linkage. Finally, we were able to detect and identify phthalate plasticizers, bis(2-ethylhexyl) phthalate (BEHP) and dibutyl phthalate (DBP), present in poly(vinyl chloride)-based food wraps.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Gas Chromatography: Types of Detectors-II
MALDI-TOF Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Atomic Fluorescence Spectroscopy
Flame Photometry: Lab
Flame Photometry: Overview