Characterization of the elemental composition of newborn blood spots using sector-field inductively coupled plasma-mass spectrometry
Related Experiment Video
Updated: Jun 11, 2026

Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Erica K Langer1, Kimberly J Johnson, Martin M Shafer
1Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota 55455, USA.
Abstract:
We developed extraction and analysis protocols for element detection in neonatal blood spots (NBSs) using sector-field inductively coupled plasma-mass spectrometry (SF-ICP-MS). A 5% (v/v) nitric acid element extraction protocol was optimized and used to simultaneously measure 28 elements in NBS card filter paper and 150 NBSs. NBS element concentrations were corrected for filter paper background contributions estimated from measurements in samples obtained from either unspotted or spotted NBS cards. A lower 95% uncertainty limit (UL) that accounted for ICP-MS method, filter paper element concentration, and element recovery uncertainties was calculated by standard methods for each individual's NBS element concentration. Filter paper median element levels were highly variable within and between lots for most elements. After accounting for measurement uncertainties, 11 elements (Ca, Cs, Cu, Fe, K, Mg, Na, P, Rb, S, and Zn) had lower 95% ULs>0 ng/spot with estimated concentrations ranging from 0.05 to >50,000 ng/spot in ≥50% of NBS samples in both correction methods. In a NBS sample minority, Li, Cd, Cs, Cr, Ni, Mo, and Pb had estimated concentrations ≥20-fold higher than the respective median level. Taking measurement uncertainties into account, this assay could be used for semiquantitative newborn blood element measurement and for the detection of individuals exposed to supraphysiologic levels of some trace elements. Adequate control of filter paper element contributions remains the primary obstacle to fully quantitative element measurement in newborn blood using NBSs.
More Related Videos
14:53In Situ Detection and Single Cell Quantification of Metal Oxide Nanoparticles Using Nuclear Microprobe Analysis
Published on: February 3, 2018
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry (CE-ICP-MS) for Quantification of Iron Redox Species (Fe(II), Fe(III))
Published on: May 4, 2020
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation