Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
Instrumentation Amplifier01:25

Instrumentation Amplifier

An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
iChip01:24

iChip

The cultivation of environmental microorganisms has long been hindered by the inability to replicate complex native conditions in vitro. The isolation chip (iChip) addresses this limitation by facilitating the growth of previously uncultivable microorganisms through in situ incubation. Designed for high-throughput microbial cultivation, the iChip comprises hundreds of microchambers, each capable of housing a single microbial cell. These microchambers are loaded with a mixture of molten agar and...
Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...
Electro-mechanical Systems01:19

Electro-mechanical Systems

Electromechanical systems are intricate configurations that effectively combine electrical and mechanical elements to achieve a desired outcome. Central to many of these systems is the DC motor, a device that converts electrical energy into mechanical motion, enabling various applications ranging from simple fans to complex robotic mechanisms.
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Nanostructured Insulated Electrodes: Fabrication and Characterization.

Langmuir : the ACS journal of surfaces and colloids·2026
Same author

In vitro blood-brain barrier models for the study of brain shuttle peptide transport.

Advances in pharmacology (San Diego, Calif.)·2026
Same author

Digitally Coded, Screen-Printed Flexible Metasurfaces for Tunable Electromagnetic Responses.

ACS applied materials & interfaces·2026
Same author

Advanced microfluidic and 3D cell culture platforms for modeling vascularization in diabetic foot ulcers: A systematic review of translational challenges and perspectives.

PloS one·2026
Same author

Nanoyeast-based impedimetric biosensor with mutated single chain antigen-binding fragment anchoring for SARS-CoV-2 detection.

Biomedical microdevices·2026
Same author

Deployment of Solid-Supported Natural Deep Eutectic Solvents via Unmanned Aerial Vehicles to Preconcentrate Contaminants from Environmental Water Samples.

ACS omega·2025
Same journal

Optimisation of Electrokinetic Extraction System: Colourimetric Determination of Copper (II) in Sand Using Polymer Inclusion Membrane.

Electrophoresis·2026
Same journal

Novel Phloroglucinol Derivatives as Neuraminidase Inhibitors Identified From Humulus lupulus L. Extract by At-Line Nanofractionation Platform.

Electrophoresis·2026
Same journal

Protein-Based High-Performance Liquid Chromatography and Cyclodextrin-Capillary Electrokinetic Chromatography for the Chiral Separation of Azoles.

Electrophoresis·2026
Same journal

Dynamics of Heparin Translocations Through Solid-State Nanopores.

Electrophoresis·2026
Same journal

Production of Protein Hydrolysates and Bioactive Peptides From Lablab purpureus and Macrotyloma uniflorum via Optimized Extraction and Proteolysis Protocols.

Electrophoresis·2026
Same journal

CMOS Electrokinetic Systems and Fabrication Approaches for On-CMOS 3D Electrodes.

Electrophoresis·2026
See all related articles

Related Experiment Video

Updated: Jun 10, 2026

Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
14:12

Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System

Published on: November 21, 2023

Instrumentation for CE and microchip-CE

Carlos D Garcia, Emanuel Carrilho

    Electrophoresis
    |July 29, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope
    14:21

    Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope

    Published on: July 24, 2021

    Related Experiment Videos

    Last Updated: Jun 10, 2026

    Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
    14:12

    Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System

    Published on: November 21, 2023

    Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope
    14:21

    Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope

    Published on: July 24, 2021