Modified calibration protocol evaluated in a model-based testing of SBR flexibility
Lluís Corominas1, Gürkan Sin, Sebastià Puig
1Laboratory of Chemical and Environmental Engineering, Institute of Environment (IMA-UdG), University of Girona, Campus Montilivi, Girona, Spain. lcorominas@icra.cat
Abstract:
The purpose of this paper is to refine the BIOMATH calibration protocol for SBR systems, in particular to develop a pragmatic calibration protocol that takes advantage of SBR information-rich data, defines a simulation strategy to obtain proper initial conditions for model calibration and provides statistical evaluation of the calibration outcome. The updated calibration protocol is then evaluated on a case study to obtain a thoroughly validated model for testing the flexibility of an N-removing SBR to adapt the operating conditions to the changing influent wastewater load. The performance of reference operation using fixed phase length and dissolved oxygen set points and two real-time control strategies is compared to find optimal operation under dynamic conditions. The results show that a validated model of high quality is obtained using the updated protocol and that the optimization of the system's performance can be achieved in different manners by implementing the proposed control strategies.
More Related Videos
08:58Atomic Force Microscopy Cantilever-Based Nanoindentation: Mechanical Property Measurements at the Nanoscale in Air and Fluid
Published on: December 2, 2022
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...