Related Experiment Video
Updated: Jun 3, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Thrombotic occlusion of an aortic-root xenograft during left ventricular assistance
Zumrut T Demirozu1, Jonathan Ho, Roberta C Bogaev
1The Center for Cardiac Support, Texas Heart Institute at St. Luke's Episcopal Hospital, Houston, Texas 77030, USA.
Abstract:
A 45-year-old man underwent repair of a congenital bicuspid aortic valve and complex aortic-root aneurysm with an aortic-root xenograft. A CentriMag® left ventricular assist device was implanted for cardiac support and was subsequently replaced with a HeartMate II® left ventricular assist device. A day later, the patient was returned to the operating room for control of bleeding, and thrombotic occlusion of the prosthetic aortic valve was detected. The patient underwent thrombus removal, oversewing of the prosthetic valve, and bypass of the left anterior descending coronary artery. This case emphasizes the hazard of bypassing a failed left ventricle with a cardiac assist device after aortic valve replacement, even with a bioprosthesis.
Related Concept Videos
Aneurysm III: Interprofessional Care