Emergency radiobioassay preparedness exercises through the NIST radiochemistry intercomparison program
Svetlana Nour1, Jerry LaRosa, Kenneth G W Inn
1National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA. Svetlana.nour@nist.gov
Health Physics
|June 29, 2011
Summary
Emergency radiobioassay labs must balance speed and accuracy. The NIST Radiochemistry Intercomparison Program (NRIP) uses performance testing to improve lab capabilities and reduce sample analysis time, crucial for radiological emergencies.
Area of Science:
- Radiochemistry
- Public Health
- Analytical Chemistry
Background:
- The international emergency radiobioassay community faces challenges in rapid, high-quality analysis of contaminated samples.
- Accurate and timely analysis is critical during radiological emergencies.
Purpose of the Study:
- To evaluate and improve the radioanalytical capabilities of laboratories involved in emergency response.
- To assess the effectiveness of performance testing programs in enhancing laboratory efficiency.
Main Methods:
- The National Institute of Standards and Technology (NIST) utilizes the NIST Radiochemistry Intercomparison Program (NRIP) for performance testing.
- NRIP includes routine and emergency performance testing scenarios.
- Metrology tools are provided to participating laboratories for self-evaluation and improvement.
Main Results:
- Radiobioassay turnaround times are 60 days for routine and 8 hours for emergency scenarios under NRIP.
- Performance testing motivates laboratories to optimize methodologies and reduce turnaround times, potentially to 3-4 hours.
- NIST continually adjusts test samples to challenge participants.
Conclusions:
- Traceable performance testing programs are essential for evaluating and improving analytical systems in response laboratories.
- The NRIP effectively enhances laboratory performance and reduces critical sample analysis times for radiological emergencies.