Related Experiment Video
Updated: May 23, 2026

06:01
Frugal Imaging Technique of Capillary Flow Through Three-Dimensional Polymeric Printing Powders
Published on: October 4, 2022
The tap-fill method for dry packing columns of rigid solids
CSH Protocols
|April 10, 2012
Abstract
No abstract available in PubMed .
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Flow Table Test
The flow table test is an established method used to assess the workability of concrete, particularly useful for evaluating highly flowable concrete mixes. This test employs an apparatus that consists of a wooden board topped with a steel plate, collectively weighing 35 pounds. The board is connected to a base via a hinge and measures 27.6 inches on each side.
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
In Vitro Drug Dissolution: Compendial Testing Models II
Various dissolution methods are utilized to assess a drug’s dissolution rate, including the flow-through cell, paddle-over-disk, cylinder, and reciprocating disk methods.The flow-through cell apparatus (USP (United States Pharmacopeia) method 4) comprises a reservoir for the dissolution medium and a pump that propels the medium through the cell containing the test sample. This method is crucial for assessing modified-release dosage forms with minimally soluble active ingredients, maintaining...
Placing Concrete
The concrete is placed as close as possible to its final position to avoid segregation. The placed concrete is then fully compacted to expel the entrapped air, and the next layer of concrete is laid while the underlying layer is still in the plastic state. The rate at which concrete is placed and compacted is kept equal.
While placing concrete, care is taken to ensure that the concrete is laid in uniform layers, and hand shoveling and moving concrete using poker vibrators is avoided. Also,...
While placing concrete, care is taken to ensure that the concrete is laid in uniform layers, and hand shoveling and moving concrete using poker vibrators is avoided. Also,...
In Vitro Drug Dissolution: Compendial Testing Models I
Compendial dissolution methods are standardized procedures defined by pharmacopeias to evaluate the rate at which a drug dissolves in a specific medium. These methods ensure batch-to-batch consistency, enable quality control, and support the prediction of drug bioavailability. They are critical for both immediate and modified-release drug products.The apparatuses used for dissolution testing differ in their design and mechanical function, but all aim to simulate the physiological environment of...
Silica Gel Column Chromatography: Overview
Silica gel column chromatography is a technique for separating compounds using a column packed with silica gel as the stationary phase. This method relies on differences in the polarity of compounds. Based on their polarities, compounds move between the stationary phase (silica gel) and the mobile phase (the solvent), forming discrete bands in the column.
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
