Speckle contrast of the sum of N partially correlated speckle patterns
Sigbjørn Vindenes Egge1, Ulf Österberg, Astrid Aksnes
1Department of Electronics and Telecommunications, Norwegian University of Science and Technology, Trondheim, Norway. sigbjoe@alumni.ntnu.no
Abstract:
In this paper a general method is presented for calculating the theoretical speckle contrast of a sum of correlated speckle patterns, motivated by the need to suppress the presence of speckle in laser projection displays. The method is applied to a specific example, where correlated speckle patterns are created by sequentially passing light through partially overlapping areas on a diffuser, before being projected onto a screen. This design makes it possible to find a simple expression for the correlation between speckle patterns. When the set of correlations involves symmetry, it is shown that the expression for the speckle contrast becomes simpler. The difference in performance between discretely and continuously varying speckle patterns is also investigated. In an example with speckle reduction by a rotating sinusoidal grating, it is found that continuous variation gives a speckle contrast that is 0.61 times the contrast obtained by discretely summing the maximum number of independent patterns.
Related Concept Videos
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
¹H NMR Signal Multiplicity: Splitting Patterns
NMR Spectrometers: Resolution and Error Correction
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...