Related Experiment Video
Updated: May 19, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Comparison of conventional parallel beamforming with plane wave and diverging wave imaging for cardiac applications:
Ling Tong1, Hang Gao, Hon Fai Choi
1Laboratory on Cardiovascular Imaging & Dynamics, Department of Cardiovascular Diseases, KU Leuven, Leuven, Belgium. ling.tong@uzleuven.be
Abstract:
When imaging the heart, good temporal resolution is beneficial for capturing the information of short-lived cardiac phases (in particular, the isovolumetric phases). To increase the frame rate, parallel beamforming is a commonly used technique for fast cardiac imaging. Conventionally, a 4 multiple-line-acquisition (4MLA) system increases the frame rate by a factor of 4, making use of a broadened transmit beam to reduce block-like artifacts. As an alternative, it has been proposed to transmit an unfocused beam (i.e., plane wave or diverging wave) for which a large number of parallel receive beams (i.e., 16) can be formed for each transmit. However, to keep the spatial resolution acceptable in these approaches, spatial compounding of overlapping successive transmits is required. As a result, the effective gain in frame rate is similar to that of a 4MLA system. To date, it remains unclear how conventional 4MLA compares to plane-wave or diverging-wave imaging when operating at similar frame rate. The goal of this study was therefore to directly contrast the performance of these beamforming methods by computer simulation. In this study, the performance of 4 different imaging systems was investigated by quantitatively evaluating the characteristics of their beam profiles. The results showed that the conventional 4MLA and plane wave imaging were very competitive imaging strategies when operating at a similar frame rate. 4MLA performed better in the near field (i.e., 10 to 50 mm), whereas plane-wave imaging had better beam profiles in the far field (i.e., 50 to 90 mm). Although diverging-wave imaging had the poorest performance in the present study, it could potentially be improved by optimizing the settings.
More Related Videos
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
07:38Real-time Monitoring of High Intensity Focused Ultrasound (HIFU) Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU)
Published on: November 3, 2015
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT