Preliminary experience with Option inferior vena cava filter.

Shams I Iqbal1, Azadeh Elmi, Sandeep Hedgire

  • 11Department of Radiology, Lahey Clinic, Burlington, MA, USA.

Summary

The Option inferior vena cava (IVC) filter demonstrated safety and efficacy in preventing fatal pulmonary embolism (PE) during short-term follow-up. High technical success was observed for filter retrieval, indicating a favorable safety profile.

Related Concept Videos

Venous Thrombosis III: Interprofessional Care01:29

Venous Thrombosis III: Interprofessional Care

Venous thrombosis requires effective prevention and treatment strategies to improve patient outcomes and reduce potential complications.Prevention StrategiesHealthcare providers must prioritize preventing venous thromboembolism (VTE) for all adult patients upon admission. Interventions depend on bleeding and thrombosis risk, medical history, current medications, diagnoses, planned procedures, and patient preferences. Patients on bed rest should change positions every two hours and, if not...
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
Cardiac Catheterization I: Pre-Procedure Overview01:28

Cardiac Catheterization I: Pre-Procedure Overview

Cardiac catheterization is an invasive diagnostic technique used to identify and evaluate structural and functional diseases of the heart and major blood vessels. This technique diagnoses congenital heart disease, coronary artery disease, valvular heart disease, and coronary spasms and assesses ventricular function. It helps guide treatment decisions, including the need for revascularization procedures like percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) and...
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...