Effect of simulated learning on blood pressure measurement skills
Gill Ballard1, Stewart Piper, Peter Stokes
1Faculty of Health and Social Care and Education, Anglia Ruskin University, Peterborough.
Aim:
To explore whether additional teaching and simulated learning of one-hour duration could improve the blood pressure measurement skills of nursing students.
Method:
A post-test experimental method was used to measure the outcome of additional, targeted simulated learning of blood pressure monitoring beyond normal curriculum content in adult branch nursing students in module one of a three-year nursing programme.
Results:
One hour of additional teaching and simulated learning improved the ability of nursing students to measure blood pressure accurately, with the data revealing a statistical difference between experimental and control groups in the systolic and diastolic accuracy of blood pressure monitoring.
Conclusion:
In a changing practice environment with fewer opportunities to develop clinical skills under supervision, there is a need for nurse educators and mentors to reconsider and research further methods used for blood pressure monitoring and other skills teaching using simulation for effective learning and skills acquisition.
More Related Videos
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
07:32Use of Galvanic Skin Responses, Salivary Biomarkers, and Self-reports to Assess Undergraduate Student Performance During a Laboratory Exam Activity
Published on: February 10, 2016
Related Concept Videos
Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...