In situ potential distribution measurement in an all-vanadium flow battery

Qinghua Liu1, Ahmet Turhan, Thomas A Zawodzinski

  • 1BRANE Lab, Department of Mechanical, Aerospace and Biomedical Engineering, The University of Tennessee, Knoxville, Tennessee 37996, USA.

Chemical Communications (Cambridge, England)
|June 6, 2013
PubMed

Related Concept Videos

Voltammograms: Overview01:16

Voltammograms: Overview

Voltammograms are current plots as a function of applied potential, offering insights into electrochemical systems. The shape of a voltammogram depends on how the current is measured and whether convection (heat transfer by fluid movement) is present or absent.
Shapes of Voltammograms
Voltammetry: Overview01:20

Voltammetry: Overview

Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
Voltammetry: Factors Affecting Measurements01:21

Voltammetry: Factors Affecting Measurements

A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
Junction Potentials in Galvanic Cells01:21

Junction Potentials in Galvanic Cells

The Nernst equation, derived under the assumption of thermodynamic equilibrium, calculates the electromotive force (emf) as the sum of potential differences at phase boundaries in a reversible cell without a liquid junction. However, in irreversible cells such as the Daniell cell, an additional potential difference named the liquid-junction potential (EJ) arises across the interface of two electrolyte solutions due to different ion diffusion rates. This EJ represents the potential difference...
Potentiometer01:30

Potentiometer

Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...